Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Environ Sci Pollut Res Int ; 28(27): 35822-35829, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1384554

ABSTRACT

This study aims to investigate the potential safety hazards and provide reference for improving the medical waste disposal procedure in SARS-CoV-2 testing laboratory. Our SARS-CoV-2 testing group detected the RNA residue on the surface of medical waste with Droplet Digital PCR, and held a meeting to discuss the risks in the laboratory medical waste disposal process. After effective autoclaving, SARS-CoV-2 contaminated on the surface of medical waste bags was killed, but the average concentration of viral RNA residues was still 0.85 copies/cm2. It would not pose a health risk, but might contaminate the laboratory and affect the test results. When the sterilized medical waste bags were transferred directly by the operators without hand disinfection, re-contamination would happen, which might cause the virus to leak out of the laboratory. Furthermore, we found that sterilization effect monitoring and cooperation among operators were also very important. In summary, we investigated and analyzed the potential safety hazards during the medical waste disposal process in SARS-CoV-2 testing laboratory, and provided reasonable suggestions to ensure the safety of medical waste disposal.


Subject(s)
COVID-19 , Medical Waste Disposal , COVID-19 Testing , Humans , Laboratories , SARS-CoV-2
2.
Sci Total Environ ; 742: 140370, 2020 Nov 10.
Article in English | MEDLINE | ID: covidwho-610881

ABSTRACT

The rapid development of global COVID-19 pandemic poses an unprecedented challenge to the safety and quality of laboratory diagnostic testing. Little is known about the laboratory surface areas and operation behaviors that may cause potential contamination in SARS-CoV-2 nucleic acid testing. This study aims to provide reference basis for the improvement of laboratory disinfection programs and personal operating protocols. In this study, we compared the qRT-PCR and ddPCR in detecting of residual virus that existed on the object surfaces from sample transportation and reception related facilities, testing related instruments, personal protective equipment and other facilities in nucleic acid testing laboratory. All samples were negative by qRT-PCR, in contrast, 13 of 61 samples were positive for SARS-CoV-2 by ddPCR. The areas with highest density of SARS-CoV-2 nucleic acid were the outer gloves of operator A (37.4 copies/cm2), followed by door handle of 4 °C refrigerator (26.25 copies/cm2), goggles of operator A (22.16 copies/cm2), outer cover of high speed centrifuge (19.95 copies/cm2), inner wall of high speed centrifuge (14.70 copies/cm2) and others. We found that all the positive objects were directly or indirectly contacted by the operator's gloved hands, suggesting that hands contact was the main transmission pathway that led to laboratory environmental contamination. In summary, ddPCR has an advantage over qRT-PCR in tracing laboratory contamination. We evaluated the risk areas and operation behaviors that may easily cause contamination, and provided recommendation for improving the laboratory disinfection programs and personal operating specifications.


Subject(s)
Betacoronavirus , Coronavirus Infections , Equipment Contamination , Pandemics , Pneumonia, Viral , RNA , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Humans , Laboratories , Nucleic Acids/analysis , Polymerase Chain Reaction , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL